Using +% and, Channel intensity, Non-intensity parameters – ETC Ion User Manual

Page 142: Channel intensity non-intensity parameters

Advertising
background image

126

Ion Operations Manual

Using +% and -%

Use +% and -% to incrementally change parameter values. To access this function on Ion, press
[Shift] & [+] or [Shift] & [-]. By default, +% and -% are assigned a value of 10. This can be changed
in Setup. This can be used with any parameter.

Channel Intensity

When channels are selected, pressing [Shift] & [+] increments the intensity level by 10 (or by the
value established in setup, see

{Manual Control}, page 104

). Alternatively, you may press [Shift] &

[-] to decrement the intensity level by 10. You may use these keys consecutively to “add to” or
“subtract from” the intensity level.

For Example:

Select channels 1 through 10 and set them to an intensity level of 45% from the keypad.

[1] [Thru] [1] [0] [At] [4] [5] [Enter]

Change the intensity level to 65% using +% which is set to its default value of 10% in the

setup menu.

[Shift] & [+] [Shift] & [+]

Non-intensity Parameters

+% and -% may be used to incrementally adjust non-intensity parameters as well.

For Example:

[1] {Iris} [Shift] & [+] [Shift] & [+]

{Zoom} [Shift] & [-] [Shift] & [-]