Interface protocols – ETC Ion User Manual

Page 359

Advertising
background image

A

Eos Configuration Utility

343

Backup Automatically Takes Control

Switches to the backup automatically if the primary should go offline.

Allowed Output Addresses

A range or ranges of addresses that can be assigned to limit the number of output addresses. The
default setting is to allow addresses 1 through 65536.

Interface Protocols

MultiConsole

Clicking in the enable box will allow for multiconsole communication on the selected port.

See

“Multi-console and Synchronized Backup” on page 357.

Network Type
This setting adjusts the timeout period before a backup device will take control from the master.

Standard - After five seconds of no response from the master, the backup will assume the

master has disconnected and will then take control.

Engineered - After 1.6 seconds of no response from the master, the backup will assume the

master has disconnected and will then take control.

Sensor Feedback

Clicking in the enable box will allow Ion to receive feedback over the network from a Sensor
rack.This option is “Enabled” by default. See

About Address, page 272

for more information.

RDM

Clicking in the enable box will allow Ion to perform RDM functionality including device discovery.
See

{Patch} Display and Settings, page 76

and

About Address, page 272

FDX Feedback

Clicking in the enable box will allow Ion to receive FDX dimmer feedback over the network.

Broadcast Type

Directed Broadcast - Broadcast packets are directed to a subnet based on the IP address

and subnet mask of the sender.

Limited Broadcast - The limited broadcast address is 255.255.255.255. It is limited because

routers will never forward datagrams with that destination address. This means that
datagrams with the limited broadcast address are confined to the particular network segment
on which they originate.

WiFi Remote

Select to allow WiFi RFRs, like the iRFR or aRFR, to connect to Ion. For additional information,
including setup, please visit the

iRFR Documentation Wiki

and

aRFR Documentation Wiki

,

www.etcconnect.com/wiki.

UDP Strings

Clicking in the enable box will allow the selected port to send UDP strings.

N o t e :

RDM requires use of a Net3 Gateway using version 5.1 or higher.