ETC SmartLink LinkPower Supply Kit User Manual

E t c, Smartlink™ linkpower supply kit, Overview

Advertising
background image

E T C

®

S e t u p G u i d e

SmartLink™ LinkPower Supply Kit

.c

n

I

,

sl

o

rt

n

o

C

e

rt

a

e

h

T

c

in

o

rt

c

el

E

1

f

o

1

e

g

a

P

n

oi

t

al

la

ts

n

I

ti

K

y

lp

p

u

S

r

e

w

o

P

k

ni

L

k

ni

L

tr

a

m

S

Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736

London, UK Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000

Rome, IT Via Ennio Quirino Visconti, 11, 00193 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486

Holzkirchen, DE Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00

Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2009 ETC. All Rights Reserved. Product information and specifications subject to change.

7024M2200 Rev B Released 2009-06

ETC intends this document to be provided in its entirety.

Overview

One SmartLink LinkPower Supply (S-LPS) powers up to four wall stations over the SmartLink™

network.

Due to the similar design for the SmartPack Wall Mount and the SmartSwitch Relay Panel control

terminations, the following instructions may be used for either product.

Installation Procedure

The LinkPower supply kit (7021K1010) includes a LinkPower supply and four screws.

Step 1:

Remove power from the control electronics.

• For a SmartPack Wall Mount, turn the Standby breaker off.
• For a SmartSwitch relay panel, turn the circuit breaker off at the breaker panel.

Step 2:

Remove the two screws securing the I/O panel to the chassis.

Step 3:

Fold the I/O panel down to reveal the control terminations.

Step 4:

Angle the LinkPower supply board approximately 10°, insert the four pins as found on the

LinkPower supply into the receptacle on the I/O board.

Step 5:

Align the LinkPower supply with the four screw mounts located on the I/O panel and

secure with the four screws provided. Do not over-tighten the screws.

Step 6:

Close the I/O panel and secure with the two screws.

Step 7:

Re-apply power to the control electronics.

If you are having difficulties, contact ETC Technical Services directly at one of the offices listed in the

contacts list below.

N o t e :

You may have only one station power source on the SmartLink network. This source

may be either the LinkPower Supply (S-LPS) or a SmartLink Station Power Module

(S-SPM) which powers up to 16 SmartLink stations. As well, you may have up to four

SmartLink host products in a SmartLink system. One SmartLink host product

(SmartPack, SmartSwitch, Unison DRd with SmartLink or Sensor + with SmartLink) in

the system must have a LinkPower Supply or Station Power Module installed for wall

station power.

Step 4

Step 5

I/O board

LinkPower

supply

Advertising