EUCHNER AS-i 3.0 PROFIBUS DP Gateway Double Master with integrated Safety Monitor for 2 AS-i networks User Manual

Commissioning / inbetriebnahme, Grundlegende bedienungshinweise

Advertising
background image

AS-i 3.0 PROFIBUS DP Gateway Double Master with integrated Safety Monitor for 2 AS-i networks

Technische Änderungen vorbehalten, alle Angaben ohne Gewähr

Id.-No.: 104137 Issue date - 9.6.08

EUCHNER GmbH + Co. KG

Seite

1

Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0

Fax. +49/711/753316

1.12A

classic mode / klassischer Modus

unterstrichene Werte sind anwählbar

underlined data can be selected

advanced display mode / erweiterter Display-Modus

Basic Operation

The device starts in the traditional mode. You can switch between the two modes with ESC or OK. In the advanced mode the
cursor is moved by the arrow buttons. Pushing OK puts you to the superior menu (in the drawing one step to the right side).
ESC puts you back to the previous menu. To edit data move with arrow buttons the marking to desired line first and then select
the item with OK, change the data by using the arrow buttons and finally press OK button to accept the input. Pushing ESC
cancels the editing.

Grundlegende Bedienungshinweise

Das Gerät startet im klassischen Modus. Mit ESC oder OK kann zwischen dem klassischen und dem erweiterten Modus
gewechselt werden. Im erweiterten Modus wird der Cursor mit den Pfeil-Tasten bewegt. OK wechselt ins nächsthöhere Menü.
ESC wechselt zurück ins vorherige Menü. Die zu editierenden Werte zunächst mit dem Cursor markieren, dann mit

kursive Einträge sind nicht immer vorhanden

items in italic are not always available

TEACHING CODES
SLAVE ADDR.

2(1)

OK
ESC

OK

SLAVE ADDR

2

ENTER CODE (1)

00000000

ESC

OK

COUPLING SLAVE
SLAVE ADDR

2(1)


ESC

OK

TEACH SAFETY
SAFE OUTPUT CH
SAFE COUPLING
START/STOP
CLEAR SAFE CFG
PIN
SAFE CHIPCARD
PROTECT
SAFE SUBST VAL

PROFIBUS
QUICK SETUP

SETUP
DISPLAY CONTRAST

AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST

SAFE COUPLING
ON CHANNEL

2

ADR

<XY>

<DISABLE>

A S - I S A F E T Y

A S - I S A F E T Y

SAFE SUBST VAL
SUBSTITUTE

CHANGE

CHANGE PIN
ENTER NEW PIN

0000
0000
OK

BANK A CONFIG
COMPLETE
CONFIGURATION:
RELAIS IMMER AN
MON. VER.: 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2

COPY BANK A TO
MONITOR
CONFIGURATION:
RELAIS IMMER AN
MON. VER.: 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2
------------------------------
RELEASE CODE
1BDF

OK

CLEAR SAFE CFG

ENTER PIN

0000
OK

START/STOP
ENTER PIN

0000
OK

CHANGE PIN
ENTER PIN

0000
OK

SAFE CHIPCARD
ACTIVE: BANK B

VIEW
CARD -> MONITOR
MONITOR -> CARD
CLEAR CODES
CLEAR SAFE CARD

STOP MONITOR?

OK

START MONITOR

OK

SELECT BANK

A
OK

SELECT BANK

A
CLEAR

CLEAR SAFE CFG

CLEAR

PROTECT
ENTER PIN

0000
OK

SELECT BANK

A
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

DOWNLOAD
NOT ALLOWED

CHANGE

TEACHING CODES
CLOSE CONTACTS

AS-I 1:
|

1-OK

2-RX |

3-RR

.... |
30-DC | 31-DC

AS-I 2:
|

1-OK

2-RX |

3-RR

.... |
30-DC | 31-DC
....
HELP
NO SAFETY SL
MS MISSING SLAVE
X CH OK
R CH RELEASED
OK CODE LEARNED
DC DUPL.CODE
ER CODE ERROR

TEACH CODES
ENTER PIN

0000
OK

TEACH CODES
COMPLETE
SINGLE SLAVE
COUPLING SLAVE
SNGL SLAVE CODE

SAFE OUTPUT
CHANNELS
CH 1: ON
CH 2: OFF
...
CH 16: OFF

TEACH CODES
ENTER PIN

0000
OK

AS-I CIRCUIT 1
AS-I CIRCUIT 2

AS-I CIRCUIT 1
AS-I CIRCUIT 2

START/STOP
STOP

CHANGE

Commissioning / Inbetriebnahme