2 technical data, electronic-key adapter, Manual eks electronic-key adapter profibus-dp – EUCHNER EKS FSA with Profibus-DP Interface User Manual

Page 12

Advertising
background image

Manual EKS Electronic-Key Adapter Profibus-DP

4.2 Technical data, Electronic-Key adapter

Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.

General parameters

Value

Unit

min.

typ.

max.

Housing

Plastic (PA 6 GF30 gray)

Degree of protection according to EN 60529

IP 67 in installed condition

Ambient temperature at UB = 24 V DC

0

+ 55

°C

Mounting cut-out acc. to DIN 43700

33 x 68

mm

Connection for power supply

Plug-in screw terminal, 3-pole,

max. conductor cross-section 1.5 mm², tightening torque

0.22 Nm

Operating voltage UB
(regulated, residual ripple < 5 %)

20 24 28

DC

V

Current consumption

150

mA

Interface, data transfer

Interface to host control

RS485

(address selectable via DIP switch)

Address range

0 ... 126

Transfer protocol

Profibus-DP according to EN 50170

Data transfer rate

9.6/19.2/45.45/93.75/187.5/500 kbps

1.5/3/6/12

Mbps

Connection for Profibus-DP

Sub-D 9-pin

Cable length max.

100 ... 1200

according to Profibus-DP, depending on data transfer rate

m

LED display

Green: "Ready" (in operation)

Yellow: "Electronic key active" *

Red: "Error"

Parameters for the outputs LA and LB (version EKS FSA only)
Power supply for load U (LA, LB)

24

30

V

Switching current per output

1

50

mA

Number of actuations of the overload
protection

100

Output voltage high for U (LA, LB)

U x 0.9

U

V

Resistance in switched-on state

35

Ohm

Capacitance per output

2

nF

Additional capacitive load per output

1

µF

Utilization category according to AC-12

EN IEC 60947-5-2 AC-15

DC-12
DC-13

50 mA / 24 V

Difference time between the outputs**
(LB first)

200

ms

Connection screw terminals, 2 x 2-pole

0.14

1.5

mm²


* The LED lights up yellow if there is a functional Electronic-Key in the Electronic-Key adapter.
** If access on the Profibus interface takes place during the insertion or removal of the Electronic-Key,
the difference time can be more than 200 ms.

092009-03-10/07

Subject to technical modifications

Page 12

/

36

Advertising