9.3.7. Interval metering

-

Interval metering is a sub-routine of metering by volume mode; repetition is not launched by

hitting a key or by a triggering pulse, but automatically after a pause selected before.

-

Set volume as described in chapter

10.3.5, metering by volume.

-

Hold "Select" key (36) depressed until LED "pause sec/min/h" is lit.

-

Enter pause with arrow keys (35); choose pause between 0.1 seconds and 750 hours.
seconds range: display 0.1 to 599.9 (no extra signal displayed)
minutes range: display 10 to 599, „'“ displayed (600sec = 10min)
hours range: display 10 to 750 "h" displayed (600min = 10Std.)

-

Hold "Select" key (36) depressed until LED "Vol min" and LED "Pause sec/min/h" is lit the

same time.

-

Interval metering is controlled with the "Start Stop" key (32) or via the interface.

-

After having hit the "Start Stop" key (32) the metered volume is displayed (41), rising from

zero to the current value, or a pause interval rising from zero to

t the value set before. The

respective LED is going to flash.

9.3.8. Adjust backstroke for metering by volume mode (fig. 48)

To avoid dripping in the "metering by volume" mode, a short backstroke of the pump may be

programmed.

-

Turn power switch (29) OFF. Hit "Cal" key (34), and, while holding depressed, turn power

switch (29) ON.

-

Pump head, e.g. "Pu 1" is displayed (41).

-

Hit arrow keys (35) until "r on" or "r off" is displayed (41).

-

"r on" turns backstroke ON, "r off" turns backstroke OFF.

-

Confirm mode with "Select" key (36)

9.4. Interfaces (fig. 49)

9.4.1. Analog interface

-

An analog interface connector (37) is installed in the item's rear panel.

-

External pump control uses this analog interface.

Control voltage of 0 - 10 volts equals rotational speed between 0 and max.

control voltage

PD 5201

PD 5206

0 - 0.9 V

0 [1/min]

0 [1/min]

1 V

5 [1/min]

24 [1/min]

10 V

120 [1/min]

600 [1/min]


Control current 4 - 20 mA equals rotational speed between 0 and max.

control current

PD 5201

PD 5206

0 - 4.9 mA

0 [1/min]

0 [1/min]

5 mA

5 [1/min]

24 [1/min]

20 mA

120 [1/min]

600 [1/min]