Hydro-Logic StealthRO200 - Upgrade Kit User Manual

Page 2

Advertising
background image

2) Push the complete membrane upgrade assembly onto the 2 mounting clips. See image below

3) Turn the unit so you are looking at the back side. Install the loose blue and black tubing on the
right side of the lower membrane housing to the corresponding "Tee" fittings. Install the "Tee"
fittings into the black automatic shut-off valve (ASOV). The "Tee" fitting with the black tubing
connects to the fitting on the (ASOV) with the black fitting collets. The black fitting collets are on
the side of the ASOV with "in" and "out" stamped onto it. The "in" side should face to the right
while the "out" side faces to the left. Connect the new flow restrictor that has "1500" on it to the
"out" fitting on the ASOV. You will need to re-use the small piece of black tube that you removed
in step #1 to connect the "1500" flow restrictor. The last step is to connect the white tubing as
shown in the picture on the next page.