Dvi interface, Usb interface, Usb interface on the front face (option) – Lenze CS 9000 DVI Operating Instructions User Manual

Page 38: Electrical installation

Advertising
background image

Electrical installation

Connecting the supply and peripheral devices
DVI interface

6

l

38

BA_CS9000DVI EN 4.0

6.3.4

DVI interface

)

Note!

Only use the DVI cable from the scope of supply or one of the DVI cables
specified in the following table, featuring a maximum length of 2 m.
Otherwise a faultless signal transmission is not guaranteed.
Greater distances can be covered with the following Lenze accessories:
2 ... 5 m: "DVI/USB" cable set
5 ... 35 m: DVI/USB extender V4

Description

Connection type

Cable type

DVI interface

DVI−D socket

DVI−D single link (18+1)

DVI−D double link (24+1)

IPC001

6.3.5

USB interface

Description

Connection type

Cable type

USB 2.0 host connection
Max. load: 5 V/500 mA

USB−A socket

USB cable with USB−A plug

IPC001

Description

Connection type

Cable type

USB

USB device connection

USB−B socket

USB cable with USB−B plug

DVI/USB−010

6.3.6

USB interface on the front face (option)

Description

Connection type

Cable type

USB 2.0 host connection with
IP 65 cover
Max. load: 5 V/500 mA

USB−A socket

USB cable with USB−A plug

EL100−013

)

Note!

If you use USB interfaces routed to the outside, the data integrity cannot be
guaranteed. On the "PC based Automation" DVD you’ll find the "FM Tool"
software which can be used to deactivate the front USB interface if it is not
needed.

Advertising