Mechanical installation

Standard devices in the power range 3 ... 22 kW

Assembly in built-in technique (standard)

5

112

EDS84ASC552 EN 9.1

5.3

Standard devices in the power range 3 ... 22 kW

5.3.1

Assembly in built-in technique (standard)

You can choose between three variants for mounting the ”built-in unit” version of the

controllers:

ƒ

Assembly without filter
– in ”standard” technique

ƒ

Assembly with filter:
– in ”standard” technique (footprint filter)
– in mounting variant (side-mounted filter)

The following filters can be used for the controllers:

ƒ

on the supply side
– RFI filters

Assembly without filter in ”standard” technique
Mounting requires four screws

ƒ

M5 x 12 mm (for devices in the power range 3 kW ... 15 kW) or

ƒ

M6 x 16 mm (for devices in the power range 18.5 kW .... 22 kW).

Screw and washer assemblies or hexagon socket screws with washers are recommended.
The mounting location and material must ensure a durable mechanical connection.
How to proceed:
1. Prepare the fixing holes on the mounting surface.
2. Screw the controller directly to the mounting surface.