Electrical installation, Important notes, 1 important notes – Lenze 8400 User Manual

Page 153

Advertising
background image

Electrical installation

Important notes

6

153

EDS84ASC552 EN 9.1

6

Electrical installation

6.1

Important notes

Danger!

Hazardous electrical voltage
Depending on the device, all power connections remain live up to 3 minutes

after the mains has been switched off.
Possible consequences:

ƒ

Death or severe injuries when touching the power terminals.

Protective measures:

ƒ

Wait for at least 3 minutes before working on the power terminals.

ƒ

Make sure that all power terminals are deenergised.

Danger!

Dangerous voltage
The leakage current to earth (PE) is > 3.5 mA AC or > 10 mA DC.
Possible consequences:

ƒ

Death or severe injuries when the device is touched in the event of a fault.

Protective measures:

ƒ

Implement the actions required in the EN 61800-5-1. Especially:

– Fixed installation

– PE connection must conform to standards (PE conductor diameter

 10 mm

2

or PE conductor must be connected twice)