3 connection of relay output, Connection of relay output, Electrical installation – Lenze 8400 User Manual

Page 219

Advertising
background image

Electrical installation

Common control terminals

Connection of relay output

6

219

EDS84ASC552 EN 9.1

6.6.3

Connection of relay output

X101

NC

COM

X101

NO

8400GG009

8400GG010

Fig. 6-32

Wiring of the relay outputs

Labelling

Description

COM

Central contact of relay

AC 250 V, 3 A

DC 24V, 2A

DC 240 V, 0.16 A

According to UL508C:

– 3 A, 250 V AC (general purpose)

– 2 A, 24 V DC (resistive)

– 0.16 A, 240 V DC (general purpose)

NC

Relay output NC (normally closed)

Position is displayed via TRIP software message

(Lenze setting)

NO

Relay output NO (normally open)

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

flexible

0.2 ... 1.5

24 ... 16

-

-

3.5 x 0.6

with wire end ferrule

Advertising