2 analog inputs and outputs, Analog inputs and outputs, Electrical installation – Lenze 8400 User Manual
Page 223
Advertising
Electrical installation
StateLine C control terminals
Analog inputs and outputs
6
223
EDS84ASC552 EN 9.1
6.7.2
Analog inputs and outputs
X3
GND
X3
O1U GA
A1I A1U
AR
+10 V /
10 mA
0 ...10 V
2 mA
1k ... 10k
0.
..
1
0
V
"
8400SLC042
8400SLC043
Fig. 6-34
Connection of the analog inputs and outputs
Labelling
Description
Controller
Reference voltage 10 V
A1U
Analog input 1
10V ( 78)
A1I
0 ...+20 mA/+4 ...+20 mA ( 78)
GA
GND analog signals
O1U
Analog output 1
0 ... +10 V ( 78)
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
0.2 ... 1.5
24 ... 16
-
-
-
With wire end ferrule
Advertising