2 analog inputs and outputs, Analog inputs and outputs, Electrical installation – Lenze 8400 User Manual

Page 230

Advertising
background image

Electrical installation

HighLine C control terminals

Analog inputs and outputs

6

230

EDS84ASC552 EN 9.1

6.8.2

Analog inputs and outputs

X3

GND-A

X3

A2I

O2I

A2U

O2U

A1I

O1I

A1U

O1U

AR

GA

+10 V /

10 mA

0 ...10 V

1k ... 10k

0

...

10

V

"

8400HLC034

8400HLC012

Fig. 6-40

Connection of the analog inputs and outputs

Labelling

Description

Controller

Reference voltage 10 V

A1U

Analog voltage input 1

10 V

 81

A1I

Analog current input 1

0 ...+20 mA/+4 ...+20 mA

A2U

Analog voltage input 2

10 V

A2I

Analog current input 2

0 ...+20 mA/+4 ...+20 mA

GA

GND analog signals

O1U

Analog voltage output 1

0 ... +10V

 81

O1I

Analog current output 1

0 ...+20 mA/+4 ...+20 mA

O2U

Analog voltage output 2

0 ... +10V

O2I

Analog current output 2

0 ...+20 mA/+4 ...+20 mA

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.2 ... 1.5

24 ... 16

-

-

-

With wire end ferrule

Advertising