3 axis bus, Axis bus, Electrical installation – Lenze 8400 User Manual

Page 239: Topline c control terminals axis bus, I/o axis bus

Advertising
background image

Electrical installation

TopLine C control terminals

Axis bus

6

239

EDS84ASC552 EN 9.1

6.9.3

Axis bus

Note!

This connection is not supported in versions below 8400 TopLine, SW version

02.00. This connection must not be wired in these lower versions.

X10

,

"

"

"

CAN-Ground

X10

CAN-Low

CAN-High

Sync/State

EDS84AVxxxx

AL

A

H

AG

R

R

CA

O

N

AB

AS

AL

A

H

AG

AS

120Ω

8400TLC002o

8400TLC009

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.2 ... 1.5

24 ... 16

-

-

-

With wire end ferrule

I/O axis bus

Labelling

Feature

Rated value

X10/AS

I/O axis bus connection

TTL level: 5 V

X10/AG

GND, reference potential: I/O axis bus