2 rated data, Rated data, Braking operation – Lenze 8400 User Manual

Page 260

Advertising
background image

Braking operation

Operation with spring-applied brake

Rated data

8

260

EDS84ASC552 EN 9.1

8.3.2

Rated data

ƒ

E82ZWBRB brake switch

Range

Values

Input voltage

1/N/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz

2/PE AC 230 V (AC 180 ... 264 V), 45 ... 65 Hz

Input current

AC 0.1 ... 0.54 A

Output voltage

DC 205 V

at AC 230 V mains voltage

Maximum brake current

DC 0.41 A

Installation in 8200 motec

DC 0.54 A

Installation in control cabinet

Control input

Control voltage

DC 24 V, PLC-level
HIGH

LOW

DC +15 ... 30 V

DC 0 ... +3 V

Control current

5 ... 10 mA

Protective function

Protected against polarity reversal until DC 60 V

Maximally connectable cable

cross-section

1.5 mm

2

AWG 16

ƒ

E82ZWBRE brake switch

Range

Values

Input voltage

3/PE AC 400 V (AC 320 ... 550 V), 45 ... 65 Hz

Input current

AC 0.1 ... 0.61A

Output voltage

DC 180 V

at AC 400 V mains voltage

DC 225 V

at AC 500 V mains voltage

Maximum brake current

(pilot duty)

DC 0.47 A

Installation in 8200 motec

DC 0.61 A

Installation in control cabinet

Control input

Control voltage

DC 24 V, PLC-level
HIGH

LOW

DC +15 ... 30V

DC 0 ... +3 V

Control current

5 ... 10 mA

Protective function

Protected against polarity reversal until DC 60 V

Min. permissible switch-off

time

t

off

>20ms

Maximally connectable cable

cross-section

1.5 mm

2

AWG 16

Advertising
This manual is related to the following products: