Safety engineering

Operating mode

10

276

EDS84ASC552 EN 9.1

10.5

Operating mode

With the integrated safety system, product key: ...B..., the following safety function can be

used:

ƒ

Safe Torque Off (STO)

If requested, the safe disconnection of the drive is achieved through:

ƒ

Directly connected active sensors

ƒ

Passive sensors connected to a safety switching device

The safety functions are suitable for applications according to IEC 61508 to SIL 3 and

achieve a performance level (PL) e and the control category 4 according to EN ISO 13849-1.

Danger!

If the request for the safety function is cancelled, the drive will restart

automatically.
You must provide external measures which ensure that the drive only restarts

after a confirmation (EN 60204).

The transmission of the pulse width modulation is safely switched (off) by the safety unit.

After this, the power drivers do not generate a rotating field. The motor is safely switched

to torqueless operation (STO).

M

SU

PWM

μC

P

C

3x

3x

X80

X80

E84ABSB005

Fig. 10-1

Operating principle of safety unit
SU

Safety unit

X80

Control terminals of safety unit (pluggable terminal strip)

C

Control section

C

Microcontroller

PWM

Pulse width modulation

P

Power section

M

Motor