Technical data

Rated data

Operation with increased power at a 500 V mains

4

62

EDS84ASC552 EN 9.1

4.2.7

Operation with increased power at a 500 V mains

The controller can be operated with increased continuous power (120% P

aN

) on a more

powerful motor. The overload capacity remains constant as if operated with a continuous

power of 100%; the information about the percentage values provided for the overload

phases still refers to rated data of 100%. Typical application cases include drives for units

with quadratic load characteristics such as pumps and fans.

Note!

Operation with increased power is only permitted ...

ƒ

With the rated data provided for the controller.

ƒ

In the stated mains voltage range.

ƒ

At switching frequencies of 2 kHz and 4 kHz.

ƒ

At a max. ambient temperature of 40 °C.

ƒ

With the stated installation types.

ƒ

With the fuses, cable cross-sections, mains chokes and filters required for

this type of operation.

ƒ

After parameterisation acc. to specification (cp. software manual

EDS84AV...)

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %