4 overcurrent operation, Technical data – Lenze 8400 User Manual

Page 71

Advertising
background image

Technical data

Overcurrent operation

4

71

EDS84ASC552 EN 9.1

4.4

Overcurrent operation

The controllers can be driven at higher amperages beyond the rated current if the duration

of this overcurrent operation is time limited. Two utilisation cycles with a duration of 15

s and 180 s are defined. Within these utilisation cycles, an overcurrent is possible for a

certain time if afterwards an accordingly long recovery phase takes place. For both

utilisation cycles, a moving average is determined separately.
Monitoring of the device utilisation (I x t) activates the set error response (trip or warning

if one of the two utilisation values exceeds the limit of 100 %. The current device utilisation

(I x t) is displayed under parameter C00064/x:

ƒ

C00064/1: Total value of the device utilisation

ƒ

C00064/2: Pulse utilisation in 15-s cycle

ƒ

C00064/3: Permanent utilisation in 180-s cycle

Type of utilisation

Utilisation cycle

Monitoring function

Condition

Code

Pulse utilisation

15 s

I

aNx

> 160 %

Display in C00064/2

Display of the maximum

value in C00064/1

Permanent utilisation

180 s

The monitoring function is

permanently active.

Display in C00064/3

Display of the maximum

value in C00064/1

Advertising
This manual is related to the following products: