Technical data

StateLine C control terminals

Analog inputs

4

78

EDS84ASC552 EN 9.1

4.6.2

Analog inputs

Labelling

Feature

Rated value

X3/A1U

Input

± 10 V

Input resistance

> 80 k

Input voltage in case of open circuit

Display ”0” (U < 0.2 V, absolute)

Sampling frequency

1 kHz (1 ms)

Accuracy

 0.1 V

Electric strength of external voltage

 15 V, permanent

A/D converter

Resolution 10 bits + sign

Error 1 digit 0.1 % relating to the final value

X3/A1I

Input

0 ... +20 mA

Parameterisable

4 ... +20 mA, fail-safe

Input resistance

215 

Input current in case of open circuit

Display ”0” (I < 0.1 mA)

Sampling frequency

1 kHz (1 ms)

Accuracy

 0.1 mA

Electric strength of external voltage

 7 V, permanent

A/D converter

10 bit resolution

Error 1 digit 0.1 % relating to the final value

X3/GA

GND, reference potential for analog signals

4.6.3

Analog outputs

Labelling

Features

Rated value

X3/O1U

Output voltage

0 ... 10 V

Output current

2 mA

Capacitive load

max 1 F

Voltage - 0 V

Display ”0” (U < 0.1 V, absolute)

Output voltage at reset

< 0.5 V

Accuracy

2 % relating to the final value

Short-circuit strength

Unlimited period

Electric strength of external voltage

Not guaranteed

X3/AR

Reference 10 V

10.5 V

Tolerance

±0.5 V

Capacitive load

max 1 F

Short-circuit strength

Unlimited period

Electric strength of external voltage

Not guaranteed

Permissible current loading

10 mA

X3/GA

GND, reference potential for analog signals