8 topline c control terminals, 1 axis bus, Axis bus – Lenze 8400 User Manual

Page 84: Technical data, Stop

Advertising
background image

Technical data

TopLine C control terminals

Axis bus

4

84

EDS84ASC552 EN 9.1

4.8

TopLine C control terminals

Devices of the TopLine C version have identical connections as described under ”HighLine

C control terminals” ( 80). The additional control terminals of the TopLine C version are

described in the following.

4.8.1

Axis bus

Note!

This connection is not supported in versions below 8400 TopLine, SW version

02.00. This connection must not be wired in these lower versions.

The axis bus connection serves to implement two functionalities:

ƒ

Synchronisation via state bus

ƒ

CAN synchronisation

I/O axis bus
The state bus is a bus system exclusively designed for Lenze controllers via which up to 20

controllers can be connected and which serves to simulate a ”release cord” function. The

state is controlled via the system module SFBDigitalOutput.

ƒ

The state bus knows the states ”OK” and ”fault”.

ƒ

The state bus is multi-master-compliant, i.e. each node connected to the state bus

can set the state bus to ”fault” by changing to LOW level.

ƒ

In the ”fault” status, all nodes activate their programmed response, e.g.

synchronised braking of the drive system.

Stop!

Do not connect an external voltage to the state bus, otherwise the function

will be disturbed.

Labelling

Feature

Rated value

X10/AS

I/O axis bus connection

TTL level: 5 V

X10/AG

GND, reference potential: I/O axis bus

Data transfer axis bus

Labelling

Feature

Rated value

X10/AH, AL

Data transfer axis bus connection

Acc. to CAN specification

Cable lengths: See CAN on board

Baud rate

from version 12.00: 800 kbit/s, constant

up to version 2.xx: 500 kbps, constant

Terminating resistor

120 , switching via DIP switch

X10/AG

GND, reference potential: Data transfer axis bus