"Batch" mode: Download applications automatically to target systems

Start the "Batch" mode

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.4

Start the "Batch" mode

DuplicateParameterSet

Defines whether the parameter set is to be duplicated or whether the target

system is replacement device:

• 0 = the target system is a replacement device

• 1 = duplicate parameter set

Inverter Drives 8400

The following values can be used additionally for Inverter Drives 8400:

• 2 = parameter set without communication parameters

• 3 = parameter set without motor parameters

Servo Drives 9400

• Target devices of this device series ignore the parameter. The parameters to

be transferred can be selected in the »Engineer« when the download data is

exported.

LECOM

Note: The "replacement device" function cannot be used in combination with

LECOM!

StartAfterDownload

Defines whether the PLC program/9400 application is to start automatically

after download has been completed:

• 0 = do not start PLC program/application

• 1 = start PLC program/application automatically.

ControllerEnableAfterDownload Activates the controller enable PLC after the script file has been processed:

• 0 = inverter remains inhibited after processing.

• 1 = inverter is automatically enabled after processing.

Key

Parameter

The standard setting is printed in bold. It is valid if no parameter is given.

Note!

The following special features have to be observed when parameters are downloaded:
A GDC file exported from the »Engineer«/ »EASY Starter« does not need to contain a

complete parameter set.

• The GDC file names have to be given for the ParameterSetFile parameter. The transfer

process writes the parameters value by value into the inverter (by analogy with the

parameter download in the »EASY Starter«).

Inverter Drives 8400 and Servo Drives 9400 device series
In order to make sure that you transfer a complete parameter set into the corresponding

target system, you have to use the L-force Loader (LFL) file exported from the

»Engineer«/»EASY Starter«.

• The LFL file name has to be given for the ApplicationFileSet parameter. The transfer

process passes through the complete download logic as for instance the initialisation

of the FB parameters.

Other Lenze device series
In order to make sure that you transfer a complete parameter set into the corresponding

target system, you have to use the GDC file exported from the »Global Drive

Control«(GDC).

• The GDC file name has to be given for the ParameterSetFile parameter. The transfer

process passes through the complete download logic, as for instance the initialisation

of the FB parameter or the download of four parameter sets (if available).