Installation and Setup Instructions:

The item numbers referenced in the following paragraphs, refer to the numbered
parts display in the diagrams shown below. LONGEVITY® has an instructional
setup installation video on our website at

www.longevity-inc.com

, which we ask that

you view prior installing the unit. The video shows the complete assembly of the
machine. The video is located in the Resources section of the website under manuals
and installation/set-up videos.

The LONGEVITY® 40i/50i Pilot Arc Plasma Cutters may or may not be dual
voltage varying by machine of purchase. Please check the back of your machine for
the noted input requirement or contact your LONGEVITY dealer for specifications.

Connecting the electrical plug to the unit

Connecting the power plug to the unit is important. Please view the proper
connection instructions below:

Wiring Introduction for 220 Volt

Danger: Read this manual completely before having your electrician attempt to wire
up or connect your machine to an electrical power source. LONGEVITY® units
should be wired by a certified electrician to insure your safety and a proper
110/220v plug match at your operating facility. Remember 220v plugs come with 3
or 4 prongs on them. Have the electrician check your existing receptacle.

Note: The power cord on single-phase machines has one ground wire and two hot
wires when connecting to 220vac. Connecting these wires properly is extremely
important. Improperly connected wires will void the warranty, affect personnel
safety, and possibly damage your machine and electrical power outlet.