MAMAC Systems PR-275 User Manual

Rohs, Technical information, Low pressure sensor

Advertising
background image

Accuracy*: ±1% FS
Overpressure: 10 PSID
Supply Voltage: 12-40 VDC
12-35 VAC (VDC output units only)
Supply Current: VDC Units - 10 mA max.
mA Units - 20 mA max.
Enclosure: 18 Ga C. R. Steel NEMA 4 (IP-65) or Panel Mount Chassis
Finish: Baked on enamel-PMS2GR88B
EMC Conformance: EN 55022, 55024, 61000-3-3,

61000-4-2, 3, 4, 5, 6 & 11
Compensated Temp Range: 25°F-150°F (-4°C-65°C)
T. C. Error: ±0.0125%/°F (.02%/°C)
Operating Temp Range: 0°F-175°F (-18°C-80°C)
Media Compatibility: Clean dry air or any inert gas
Environmental: 10-90%RH Non-Condensing
Termination: Unpluggable screw terminal block
Wire Size: 12 Ga max.
Load Impedance: 1.6K ohms max. at 40 VDC (mA output units)

1K ohms min. (VDC output units)
Weight: Enclosure - 1.0 lbs. (.45 kg)

Panel Mount - 0.5 lbs. (.25 kg)

PACKAGING

RANGE

OUTPUT

SPECIFICATIONS

Inspection -

Inspect the package for damage. If damaged, notify the

appropriate carrier immediately. If undamaged, open the package and

inspect the device for obvious damage. Return damaged products.

Requirements

Mounting

274 (enclosure)

275 (panel mount)

R1

("wc)

R2

("wc)

R3

("wc)

R4

("wc)

R5

(pa)
R6

(pa)

R7

(pa)

R8

(pa)

0 TO 0.10 / -0.05 TO +0.05

0 TO 1.0 / 0 TO 0.5 / 0 TO 0.25 /

-0.5 TO +0.5 / -0.25 TO +0.25 /

-0.125 TO +0.125

0 TO 5.0 / 0 TO 2.5 / 0 TO 1.25 /

-2.5 TO +2.5 / -1.25 TO +1.25 /

-0.625 TO +0.625

0 TO 30 / 0 TO 15 / 0 TO 7.5 /

-15.0 TO +15.0 / -7.5 TO +7.5 /

-3.75 TO + 3.75

0 TO 25 / -12.5 TO +12.5

0 TO 250 / 0 TO 125 / 0 TO 62.5 /

-125 TO +125 / -62.5 TO +62.5 /

-31.25 TO +31.25

0 TO 1250 / 0 TO 625 / 0 TO 312.5 /

-625 TO +625 / -312.5 TO +312.5 /

-156.25 TO +156.25

0 TO 7500 / 0 TO 3750 / 0 TO 1875 /

-3750 TO +3750 / -1875 TO +1875 /

-937.5 TO +937.5

(4-20 mA

2-wire)

(0-5 VDC or

0-10 VDC field

selectable)

mA

VDC

For Additional Information See PR-274/275 Data Sheet

INSTALLATION

Model PR-274/275

Technical Information

TI.274/275-06

LOW PRESSURE SENSOR

Warning:

Disconnect power supply before installation to prevent electrical

shock and equipment damage.

Make all connections in accordance with the job wiring diagram

and in accordance with national and local electrical codes. Use

copper conductors only.

Caution:

Use electrostatic discharge precautions (e.g., use of wrist straps)

during installation and wiring to prevent equipment damage.

Avoid locations where severe shock or vibration, excessive

moisture or corrosive fumes are present. NEMA Type 4 housings

are intended for outdoor use primarily to provide a degree of

protection against wind-blown dust, rain, and hose-directed water.

Do not exceed ratings of the device.

The PR-274/275 must be mounted as indicated by the arrows on

the enclosure. Refer to

Figure 7 for mounting dimensions.

1. Remove the transducer cover using a Phillips head
screwdriver.
2. Select the mounting location.
3. Mount transducer on a vertical surface with two #8
self-tapping screws (not provided).
4. Transducer must be mounted above the pressure pick-up or a

J-Loop must be incorporated in the tubing to function as a
condensate trap.

5. Pull wires through bottom of enclosure and make
necessary connections.
6. Replace cover and make pneumatic connections.

Tools (not provided)

- Digital Volt-ohm Meter (DVM)

- Appropriate screwdriver for mounting screws

- Appropriate drill and drill bit for mounting screws

Appropriate accessories

Two #8 self-tapping mounting screws (not provided)

Training:

Installer must be a qualified, experienced technician

Wiring

Use maximum 12 AWG wire for wiring terminals. Use flexible 1/4"
O.D. 5/32" I.D. tubing for the high and low pressure connections.
Refer to

Figures 1, 2, 3, & 4 for wiring information and Figures 5 &

6 for switch designations.

(Wiring Instructions continued on pages 2 and 3.)

8189 Century Boulevard • Minneapolis, MN 55317-8002 • USA

800-843-5116 • 952-556-4900 • Fax 952-556-4997

[email protected] • www.mamacsys.com

ORDERING INFORMATION

RoHS

Enclosure Mount

Transducer

Panel Mount

Transducer

Caution:

Condensate or moisture must not enter pressure sensor ports