MAMAC Systems PR-243 User Manual

Rohs, Model pr-243, Technical information

Advertising
background image

Accuracy*: ± 1% FS
Maximum Pressure: 40 PSIG
Supply Voltage: 12–40 VDC

12–35 VAC (VDC output units only)
Supply Current: VDC Units – 10 mA max.

mA Units – 20 mA max.
Enclosure: 18 Ga C. R. Steel NEMA 4 (IP-65)
Finish: Baked on enamel – PMS2GR88B
EMC Conformance: EN 55022, 55024, 61000-3-3,

61000-4-2, 3, 4, 5, 6 & 11
Compensated Temp Range: 0°F to 180°F (-18°C to 82°C)
T. C. Error: ±0.025%/°F (.03%/°C)
Media Compatibility: Clean dry air or any inert gas
Port Connection: 5/32" I.D.; 1/4" Brass Hose Barb
Environmental: 10–90%RH Non-Condensing
Termination: Unpluggable screw terminal block
Wire Size: 12 Ga max.
Load Impedance: 3K ohms max. at 40 VDC (mA

output units)
1K ohms min. (VDC output units)
Weight: Enclosure 1.0 lbs. (.45 kg)

*Includes non-linearity, hysteresis and non-repeatability

SPECIFICATIONS

Inspection

Requirements

Mounting

For Additional Information See PR-243 Data Sheet

INSTALLATION

8189 Century Boulevard • Minneapolis, MN 55317-8002 • USA

800-843-5116 • 952-556-4900 • Fax 952-556-4997

[email protected] • www.mamacsys.com

Model PR-243

Technical Information

TI.243-06

PNEUMATIC PRESSURE SENSOR

Inspect the package for damage. If damaged, notify the

appropriate carrier immediately. If undamaged, open the

package and inspect the device for obvious damage.

Return damaged products.

Warning:
Do not use on oxygen service, in an explosive/hazardous

environment, or with flammable/combustible media.

Disconnect power supply before installation to prevent

electrical shock and equipment damage.

Make all connections in accordance with the job wiring

diagram and in accordance with national and local

electrical codes. Use copper conductors only.

Caution:
Use electrostatic discharge precautions (e.g., use of wrist

straps) during installation and wiring to prevent equipment

damage.

Avoid locations where severe shock or vibration, excessive

moisture or corrosive fumes are present. NEMA Type 4

housings are intended for outdoor use primarily to provide

a degree of protection against wind-blown dust, rain, and

hose-directed water.

Do not exceed ratings of the device.

The PR-243 must be mounted on a vertical surface with the

1/4" brass hose barb pointing left or right. Refer to

Figure 7 for

mounting dimensions.
1. Remove the transducer cover using a Phillips head

screwdriver.

2. Select the mounting location.
3. Mount transducer on a vertical surface with two #8 self-tapping

screws (not provided).

4. Pull wires through bottom of enclosure and make necessary

connections.

5. Replace cover and make pneumatic connections.

Tools (not provided)

- Digital Volt-ohm Meter (DVM)

- Appropriate screwdriver for mounting screws

- Appropriate drill and drill bit for mounting screws

Appropriate accessories
Two #8 self-tapping mounting screws (not provided)
Training: Installer must be a qualified, experienced technician

Wiring

Use maximum 12 AWG wire for wiring terminals. Use flexible

1/4" O.D., 5/32" I.D. tubing for pressure connections. Refer to

Figures 1, 2, 3, & 4 for wiring information. and Figures 5 & 6 for

switch designations.

(Wiring Instructions continued on pages 2 and 3.)

RANGE

OUTPUT

R1 (psig)

R2 (psig)

R3 (psig)

R4 (kPa)

0 to 20 / 0 to 10 / 0 to 5

0 to 30 / 0 to 15 / 0 to 7.5

3 to 15

0 to 140 / 0 to 70 / 0 to 35

(4–20 mA 2-wire)

(0–5 VDC/0–10 VDC

field selectable)

mA

VDC

R5 (kPa)

R6 (kPa)

0 to 200 / 0 to 100 / 0 to 50

20 to 100

ORDERING INFORMATION: PR-243-

RoHS

Advertising
Table of contents