Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157880100

Instruction

Sheet

INSTALLATION INSTRUCTIONS

FOR AKTPFCC CONNECTOR KIT
FOR USE WITH PRESCOLITE ONE/TWO CIRCUIT ARCHITRACK SYSTEM ONLY.
READ INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE TRACK SYSTEM
SAVE INSTRUCTIONS FOR REFERENCE WHEN MAKING ADDITIONS TO OR CHANGES IN THE TRACK SYSTEM.

INSTALLATION

1. Refer to PRESCOLITE AKT series track for track installation instructions

2. Carefully measure outlet box mounting holes. Position screw location holes carefully on plastic side of box cover. If mounting

holes align with knockouts in metal plate. Pierce the plastic cover with a sharp tool then punch out the knockout through this hole.

3. Remove box cover mounting screw or screws. Remove knockout from back plate of connector. Position respective connector

(LIVE-END,X,L,T) over box cover to select proper mounting hole. Secure with box cover mounting screw.

4. Warning be sure power is disconnected. Pull wiring into connector. Install track and connector with instructions provided with

PRESCOLITE AKT system.

5. Secure box cover to outlet box with screws provided with outlet box.

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

INSTALLATION INSTRUCTIONS

ARCHITRAK

®

SYSTEM

BOX COVER MOUNTING SCREW

WARNING:

WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY

PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. READ ALL INSTRUCTIONS.

DO NOT INSTALL THIS TRACK IN DAMP OR WET LOCATIONS. DO NOT INSTALL

ANY PART OF TRACK SYSTEM LESS THAN 5 FEET ABOVE FLOOR. DO NOT

INSTALL ANY FIXTURE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY

CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL. DISCONNECT ELECTRICAL

POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION OF THE

TRACK. DO NOT ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING

TRACK FIXTURES ON THE TRACK. TO REDUCE THE RISK OF FIRE AND

ELECTRIC SHOCK, DO NOT ATTEMPT TO CONNECT POWER TOOLS,

EXTENSION CORDS, APPLIANCES, AND THE LIKE TO THE TRACK.