INSTALLATION INSTRUCTIONS - MODEL UR-1

UNIVERSAL RELAY MODULE

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

C NO C NO - NO C NC - NO C NC

- +

TRIG A TRIG B

RELAY A

RELAY B

PWR

w

D

A

w

D

B

1
2
3
4

J1

UR-1

UR-1 UNIVERSAL

RELAY MODULE

Fits all SDC Power Supplies. Requires

1 Module space. Supplied with mounting
screws and standoffs for J-box mounting.

C NO C NO

- NO C NC

- NO C NC

- +

TRIG A TRIG B

RELAY A

RELAY B

PWR

w

D

A

w

D

B

1
2
3
4

J1

UR-1

INPUT VOLTAGE

INPUT CONTROLLER CURRENT

12 or 24VDC +/- 10%

120/175mA

OUTPUTS

2 ea 10 amp @ 30VDC (resistive) SPDT Lock Outputs
(Configurable Wet or Dry). Wet output voltage is the
same as the module power IN voltage.

UR-1 TECHNICAL SPECIFICATIONS

DIMENSIONS

3.20"W x 2.00" L x 1.0" H
[81.28mm W x 50.8mm L x 25.4mm H]

INPUTS

2 ea Dry Signal Inputs

Field selectable relay modes include:

- Conventional Relay (CR)
- Dual Conventional Relay (2X CR)
- Time Delay Relay (TD) – 1 to 60 Seconds
- Dual Time Delay Relay (2X TD)
- Latching Relay (LR) – Separate Latch and Release Inputs
- Dual Latching Relay – (2X LR) Pulse On, Pulse Off Inputs
- Time Delay/Latching Relay
- Interlock A (airlock)
- Interlock B (2 modules required)

FEATURES AND BENEFITS

Microprocessor based relay controller that provides
multiple, field selectable operational modes for up to
two door stations.

Each output relay is field selectable as a dry contact
or voltage output.

Centralized wiring for all locks, access controls,
monitoring contacts and peripheral equipment.

1 or 2 controllers may be installed in SDC 600 series
power supplies

P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd Rev H 04-14 Page 1