background image

FIXTURE
ARM

FLAT WASHER

1/2" HEX BOLT

LOCKWASHER

AFTER LEVELING FIXTURE THAT
IS ATTACHED TO MAST ARM PIPE,
USE HOLE IN MAST ARM FITTER TO
FIELD DRILL HOLE THROUGH PIPE.

OR MAINTENANCE

WARNING:

DISCONNECT POWER BEFORE INSTALLATION

CIMARRON LED
FIXTURE

SCREW

SAVE THESE INSTRUCTIONS

CIMARRON CL1

MAF

INSTALLATION INSTRUCTIONS

1. MOUNTING MAST ARM FITTER TO FIXTURE ARM AND TO MAST ARM PIPE

Remove Arm Cover by removing the (4) Screws.

Attach Fixture to Mast Arm Fitter with (2) ½” Hex Bolts, Lockwashers and Flatwashers. Torque bolts to

approx. 42 Ft-Lbs.

Engage (4) 3/8-16 X ¾” Set-screws to the cast Mast Arm Fitter.

Slip Arm Fitter onto Mast Arm and adjust Fixture orientation while tightening the (4) Set-screws.

After Leveling the Fixture attached to the Mast Arm, use holes on each side of Mast Arm Fitter to Field Drill

13/32” dia. hole through the Mast Pipe Arm.

Remove Arm Fitter and Fixture from Mast Arm Pipe and Pull the supply wires from Mast Arm Pipe

through Mast Arm Fitter and into the Fixture Arm.

Slip Mast Arm Fitter with Fixture back onto the Mast Arm Pipe, Install the 4” long Bolt and tighten the

(4) Set-screws to approx 18 Ft-Lbs.

Secure 4” Bolt with Flatwasher, Lockwasher, and Nut (Hardware Included). Torque the Bolt and Nut to

approx. 20 Ft-Lbs.

WARNING: FAILURE TO INSTALL THE LONG BOLT COULD POSSIBLY ALLOW THE FIXTURE TO

ROTATE OR DISENGAGE FROM THE PIPE ARM.

ARM COVER

MAST ARM FITTER

MAST ARM PIPE

FLATWASHER, LOCKWASHER, NUT

3/8" SET-SCREWS

4" LONG BOLT

2.

WIRING (See Fig.

2)

POWER MUST BE OFF.

(WIRING MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN)

Wire service leads to fixture power leads according to local and National Electric Codes.

Luminaire is equipped with universal voltage drivers capable of 120V-277V input.

An optional 347/480 V input transformer is available.

Wire connections to be made inside Arm with Fixture Wires and Supply Wires (by others).

For direct wire connections, connect ground wire to green wire, connect black to black and

white to neutral then push connections back inside Arm and attach Arm Cover.

See Installation Instructions for Cimarron LED, P/N 93034033.

FIGURE 2
ARM

COVER

REMOVED

ARM

FIXTURE WIRES

SUPPLY WIRES

MAST ARM FITTER

701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000

www.spaulding-ltg.com

93037602 REV B