Specifications, Operating system requirements, Standard equipment – UVP GelMax Imager User Manual

Page 5

Advertising
background image

GelMax Imager

5

Specifications

Power Requirements:

100/115V, 60Hz; 2.0 Amps

230V, 50Hz; 2.0 Amps

Mains supply voltage fluctuations are not to exceed 10 percent of the
nominal supply voltage

Pollution Degree:

2

Installation Category:

II

Altitude:

Up to 2000m

Ambient Temperature:

5°C to 40°C

Humidity:

Maximum relative humidity of 80% for temperatures up to 31°C,
decreasing linearly to 50% maximum relative humidity at 40°C

Operating System Requirements

Windows 7 or XP, 32-bit or 64-bit

Internet Explorer 6.0 or higher

Intel Pentium Processor or equivalent, 1.6 GHz or higher

2 GB of RAM or greater

200 MB of available hard disk space for the program, more for data

CD-ROM drive

One Universal Serial Bus (USB) port for connecting the GelMax unit

Color monitor, supporting at least 1024 x 768 resolution and 16-bit or better colors; 24-bit or 32-bit
color is strongly recommended

NOTE: For 21 CFR Part 11 support functionality, the computer partition must be formatted with NTFS. Refer
to the Doc-ItLS software manual for instructions.

Standard Equipment

Darkroom

The GelMax darkroom is light tight, providing optimal imaging conditions. Darkroom features include:

Epi (overhead) LED white light

Slide-out five position emission filter wheel

Slide-out, long life transilluminator with UV safety interlock switch and manual override to
enable transillumination when the transilluminator is not closed

Doc-ItLS Acquisition and Analysis Software

UVP’s Doc-ItLS software loads directly onto the user’s existing computer. The software controls the
camera acquisition functions, enhancement and reporting features, and analysis capabilities for 1D and
colony counting functions. For information on the installation and use of the software, refer to “Installing
the Doc-ItLS Acquisition and Analysis Software” in this manual or to the Doc-ItLS Software help files.

UV Transilluminator

A long life, slimline 302nm UV transilluminator is integrated into the front slide-out transilluminator tray.
The transilluminator provides highly uniform 302nm UV transillumination across an 11.5 x 16cm imaging
area. The transilluminator is designed to accommodate a variety of Interchangeable Sample Plates, as
described below.

CAUTION: All UVP transilluminators are powerful sources of UV radiation that will cause damage to
unprotected eyes and skin. Before operating, be sure all personnel in the area are properly protected.

Advertising