Viewing and clearing events, To view the event queue, Events – Rockwell Automation 7000 DPI Wireless Interface Module User Manual

Page 52: Viewing and clearing events -4

Advertising
background image

4-4

Troubleshooting

The WIM maintains an event queue that reports the history of its actions.
You can view the event queue with the following tools:

• For Pocket PCs, use Pocket DriveExplorer for Pocket PC software

(version 1.01 or higher).

• For laptop or desktop computers, use DriveExplorer software

(version 4.04 or higher), DriveExecutive software (version 3.01 or
higher).

• An LCD PowerFlex 7-Class HIM.

To view the event queue

1. Access the event queue using a configuration tool.

2. Scroll through events in the event queue.

Events

Many events in the Event queue occur under normal operation. If you
encounter unexpected communications problems, the events may help
you or Allen-Bradley personnel troubleshoot the problem. The following
events may appear in the event queue:

DPI Product Event List

Viewing and Clearing Events

Event

Description

Control Disabled

The WIM has sent a “Soft Control Disable” command to the DPI drive.

Control Enabled

The WIM has sent a “Soft Control Enable” command to the DPI drive.

DPI Bus Off Flt

A bus-off condition was detected on DPI. This event may be caused by loose or
broken cables or by noise.

DPI Fault Clear

The DPI drive has issued a fault clear message.

DPI Fault Msg

The drive entered a faulted state.

Dup. Port Flt

Another peripheral with the same port number is already in use.

EEPROM Sum Flt The EEPROM in the WIM is corrupt.
Host Sent Reset

The DPI drive issued this event because it was reset.

Message Timeout

The DPI drive did not respond to a message request. Verify the cables are
correct.

No Event

Empty event queue entry.

Normal Startup

WIM initially powered up or was reset.

Online @ 125kbps The WIM and DPI drive are communicating at 125kbps.
Online @ 500kbps The WIM and DPI drive are communicating at 500kbps.

Advertising