Keypad Module Description

Enter
Pressing this key causes the current value
displayed to be entered into memory (only
while in the Program mode). When you press
this key the Program Mode Indicator remains
on, but stops flashing.

Escape
The ESCape key allows you to toggle
between the Display and Program modes.
When the Program mode is active, this key
will disable the editing of a parameter value.

Select
The SELect key enables editing of a parame-
ter value when the Program mode is active.
When you press this key the Program Mode
Indicator flashes.

Up/Down Arrow Keys
Use the Up/Down Arrow keys to scroll
through a list of parameters, or increase
and decrease parameter values. Press and
hold either key to increase scrolling
speed.

Real time frequency adjustment can be
achieved when using P58-[Internal
Frequency]. Refer to the User Manual
for further information.

Start
The Start key initiates a start command when
the controller is programmed for local
start/stop control (P46 - [Input Mode] is set
to “2”).

Stop
Pressing the Stop key will cause the motor to
stop, using the selected stop mode. Refer to
the P34 - [Stop Mode] parameter.

If the drive has stopped due to a fault, press-
ing this key will clear the fault.

Reverse (Change Direction)
Pressing this key causes the motor to ramp
down to 0 Hz and then ramp up to its set
speed in the opposite direction.

When the motor is running, pressing this key
causes the (currently illuminated) LED to
flash, indicating motor rotation while decel-
erating to zero. The other LED will illumi-
nate indicating the commanded direction.

Direction LEDs (Indicators)
The appropriate LED will illuminate continu-
ously to indicate the commanded direction of
rotation. If the second LED is flashing, the
drive has been commanded to change direc-
tion, but is still decelerating

.

Important: Actual motor rotation could be
different if motor leads are not connected
properly. Refer to Chapter 4 of the User
Manual for details on how to verify motor
rotation.

Parameter Number Display
These two digits display the active parameter number
for both Display and Program Group parameters.

Program Mode Indicator
When the Program Mode Indicator flashes, you can edit
the parameter value. When the Display Mode is active,
the indicator will not be lit.

Parameter Value/Fault Number
These four digits display the parameter value or fault
code number.

IMPORTANT: This publication is designed as a reference
tool. The 160 SSC User Manual (publication 0160-5.9) must
be consulted for more detailed information about parameters,
faults and hazards of personal injury.