Powerflex 753 main control board – Rockwell Automation 21G PowerFlex 750-Series AC Drives User Manual

Page 210

Advertising
background image

210

Rockwell Automation Publication 750-IN001N-EN-P - April 2014

PowerFlex 750-Series AC Drives

PowerFlex 753 Main Control Board

Table 36 - 753 Main Control Board Details

Table 37 - J4 Input Mode Jumper

No. Name

Description

HIM Connector

DPI Port 1 (HIM Cradle) connection.

Fan Connector

Power supply for internal cooling fan (Frames 2 & 3).

Battery Receptacle

User installed CR1220 lithium coin cell battery provides power to the
Real Time Clock (Optional, not supplied). Preserves the Real Time Clock
setting in the event power to the drive is lost or cycled.

ENABLE Jumper

Hardware enable jumper. TB3 becomes an Enable when this jumper is
removed.

SAFETY Jumper

Safety enable jumper. Removed when safety option is installed.

Jumper J4 Input Mode

Analog input mode jumper. Selects voltage mode or current mode.

TB1

I/O terminal block.

DPI Port 2

Cable connection for handheld and remote HIM options.

TB3

Digital input terminal block. See Important at

Table 40

.

TB2

Relay terminal block.

Jumper Position

Voltage Mode

Current Mode


J4

3 1

4 2

J4

3 1

4 2

Advertising
This manual is related to the following products: