1609-PSB1

Service Bypass Switch

Entire contents copyright © 2006 by Rockwell Automation corporation. All rights

reserved. Reproduction in whole or in part without permission is prohibited.

A-B and Allen-Bradley are registered trademarks of Rockwell Automation Corporation.

All other trademarks are the property of their respective owners.

90-007 rev 1

Note: Read the safety information sheet before installation.

Illustrations in this document may differ slightly from the actual hardware.

Attention: This product is for use in a controlled environment. Refer to product
specifications for environmental limits.

R

ACK

M

OUNTING

n

o

Set SBP in the rack. If hardwiring is required, see Connecting Power

section before screwing into the rack.

n

W

ALL

M

OUNTING

41063-300-01(1)

o

Whenever possible, attach one top screw and one bottom screw into a wall stud. If stud

mounting is not possible, use an expandable wall anchor. Screws are not included; .25” x
2” lag bolts are recommended.

T

OWER

O

PTION

n

Remove screw from the top and bottom rear of both the UPS and SBP. Install tie

brackets and reattach screws.

o

Unscrew and remove top cover of the

UPS.

p

Attach bracket to top of UPS and SBP.

q

Reattach top cover of the UPS.


Note: The 1609-SBP1, when used in conjunction with an 1609-P3000A or 1609-P5000E UPS in a tower
configuration without an external battery pack 1609-PXBP, is suitable for mounting on concrete or other
non-combustible smooth surfaces only.

41063-300-01(1)

U

SER

C

ONFIGURABLE

Attention: When using an online UPS, put the UPS in automatic bypass mode before
rotating the SBP switch.

1. Normal: Power is directed from the utility outlet, through the Bypass Panel and UPS,
and to connected equipment. For use during normal UPS operation.

2. Test: Power supplied to the UPS is not output. Use when tests are being conducted on
the UPS, and connected equipment is not yet desired.

3. Bypass:
Power from the utility outlet is filtered through the Bypass Panel, and to the
connected equipment. Use to bypass the UPS, when functioning improperly.

Note: While operating in ‘Test’ or ‘Bypass’ mode, power to the connected equipment is
not conditioned by the UPS. At this time, the “Equipment Protection Policy” is not valid.

I

DENTIFYING THE

P

ANEL

Service Bypass Panels will differ. Refer to chart for unit specifications.

Note: HW= Hardwire

Service Bypass

Panel

Corresponding

UPS Systems

Bypass

Input

UPS

Input

UPS

Output

PDU

Panel

1609-PS

B

1

1609-P3000A
1609-P3000H
1609-P5000E
1609-P8000E

1609-P10000E

HW (1Ph)

HW (1Ph)

HW

HW

*

For loads exceeding 3kVA, hardwiring is necessary.

41063-300-01(1)

x4

x4

x4

x8

Rear

Front

x1

x4

x8

x2

x2

x2