Rockwell Automation 1336S PLUS II Analog Interface Inst. User Manual

Analog interface option board installation, Instructions, Plus

Advertising
background image

Instructions

This publication will guide you through installation (including
mounting and setup) of the 1336

PLUS

II

Analog Interface Option

Board(s).

Option Board Installation

1. Remove and lock-out all incoming power to the drive. Remove/

open the drive cover.

2. Using the following table, verify that you have the correct option

board and note the slot designation for installation.

!

ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing
or repairing this assembly. Component damage may result
if ESD control procedures are not followed. If you are not
familiar with static control procedures, reference A-B
publication 8000-4.5.2, “Guarding Against Electrostatic
Damage” or any other applicable ESD protection handbook.

!

ATTENTION: To avoid a shock hazard, assure that all
power to the drive has been removed before proceeding. In
addition, verify that the DC bus has discharged by
measuring across the “+DC” and “–DC” terminals of TB1
with a voltmeter. The voltage should be 0.0VDC.

Catalog
Number

Description

Must be
Installed in . . .

1336F-LA2

Two Isolated Configurable Inputs

Slot A

1336F-LA6

One Isolated Bi-polar Input (

±

10V or

±

20mA)

and One Isolated Thermistor Input

1336F-LA7

One Isolated Bi-polar Input (

±

10V or

±

20mA)

and One Isolated Configurable Input

1336F-LA1

Single-ended, Non-isolated Configurable
(including Pot) Input & 2 Single-ended, Non-
isolated Outputs (1 - Configurable, 1 - 20mA)

Slot B

1336F-LA3

Two Isolated Configurable Outputs

1336F-LA4

One Isolated Configurable Input & Output

1336F-LA5

Isolated Pulse Input, Non-isolated Pulse Output
& Single-ended, Non-isolated Configurable
Output

1336

PLUS

II

Analog Interface

Option Board Installation

Advertising