Shunt resistor wiring example – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual
Page 194
Advertising
194
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Appendix A
Interconnect Diagrams
Shunt Resistor Wiring
Example
Refer to the
External Shunt Resistor Connections
for the Bulletin
2097 external shunt resistor catalog numbers available for Kinetix 5500 servo
drives.
Figure 90 - Shunt Resistor Wiring Example
Refer to the Kinetix 300 Shunt Resistor Installation Instructions, publication
IMPORTANT
Before wiring the Bulletin 2097 external shunt to the RC connector, remove the
wires from the servo drive internal shunt. Do not connect internal and external
shunt resistors to the drive.
DC+
SH
2198-Hxxx-ERSx
Kinetix 5500 Drive
2097-Rx
Shunt
Resistor
Shunt (RC)
Connector
Internal Shunt