Entity parameters – Rockwell Automation 1797-IE8NF FLEX Ex 8 Input Analog, HART and Noise Filter Module User Manual

Page 41

Advertising
background image

FLEX Ex 8 Input Analog, HART, and Noise Filter Analog Modules 41

Publication

1797-5.5 - September 2011

Entity Parameters

1797-IE8 and 1797-IE8NF CE, CENELEC I/O Entity Parameters

Measurement input (sig to -) for channels 0…7 (terminals: 1…2; 5…6; 9…10;
13…14; 18…19; 22…23; 26…27; 30…31)

Source output (+ to sig) for ch 0 to ch 7

(terminals: 0 to 1; 4 to 5; 8 to 9; 12 to 13; 17 to 18; 21 to 22; 25 to 26; 29 to 30)

Agency Certification

CENELEC

II (1) 2G Ex ib[ia] IIC T4

II (1) D [Ex iaD

FM

Intrinsically safe Class I, Div 1, Groups A, B, C, D, T4.
Associated Apparatus with intrinsically safe
Connections Class I, II, III, Div 1, Groups A--G
Intrinsically safe Class I, Zone 1, AEx ib[ia] IIC T4.

IECEx [Zone 0] Ex ib[ia] IIC T4

[Ex iaD]

Certificates

CENELEC DMT 98 ATEX E 020 X

FM FM Certificate Number 3009806

IECEx IECEx BVS 09.0030X

Protection Group

Allowed
Capacitance

Allowed
Inductance

U

o

= 5V

I

o

= 1 mA

P

o

= 1.3 mW

Ex ia

IIB

1000 µF

1 H

U

i

= 28V

I

i

= 110 mA

C

i

and L

i

negligible

IIC

100 µF

1 H

Protection Group

Allowed
Capacitance

Allowed
Inductance

U

o

= 23.7V

I

o

= 92.5 mA

P

o

= 548 mW

Ex ia

IIB

560 nF

10 mH

IIC

66 nF

2.5 mH