Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual

Page 118

Advertising
background image

Publication 2098-IN005C-EN-P — March 2008

118

Interconnect Diagrams

This is the power wiring diagram with 24V dc control string for
2098-DSD-HVxxx-xx and 2098-DSD-HVxxxX-xx Ultra3000 drives. For
the control string diagram with 120V ac input refer to the figure on
page 130.

Typical Power Wiring of Ultra3000 (460V) System

TB1

DC+

DC-

W

V

U

L2

L3

CN1

43

44

L1

TB2

1

2

3

L3

L2

L1

L1 AUX

L2/N AUX

43

44

CN1

43

44

2098-DSD-HVxxx-xx and

2098-DSD-HVxxxX-xx

Ultra3000

Digital Servo Drives

Note 14

AC Input Power
Connections

Motor Power
Connections

Three-phase

AC Line Filter

Note 7

Three-phase Input
230-480V ac RMS

Fused Disconnect

or Circuit Breaker *

Note 1

Isolation

Transformer *

Note 2

Chassis

Bonded Cabinet
Ground Bus *

Terminal Blocks *

Note 3

To additional

Ultra3000 drive

Three-phase

Motor Power

Connections

Note 12

Cable Shield
Clamp
Note 9

STOP *

START *

CR1 *

CR1 *

CR1 *

M1 *

Refer to Attention statement (Notes 10, 11)

N.O. Relay Output+

N.O. Relay Output-

Note 22

24V dc

Neutral

M1 *

Note 8

External Passive
Shunt Connections
(refer to examples
beginning on page 119)

Input Fusing*

Notes 4 and 5

Three-phase AC Line

50/60 Hz

Note 6

Input Fusing *
Notes 4 and 5

* Indicates User-supplied Component