Controlling a brake example – Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual

Page 131

Advertising
background image

Publication 2098-IN005C-EN-P — March 2008

Interconnect Diagrams

131

Controlling a Brake
Example

The relay output of the Ultra3000 drive (pins CN1-43 and CN1-44) is
suitable for directly controlling a motor brake, subject to the relay
voltage limit of 30V dc, and the relay current limit of 1 A dc. For brake
requirements outside of these limits, an external relay must be used. If
a transistor output is used, a control relay is also required.

Coil Currents Rated at

<

1.0 A

Coil Currents Rated at >1.0 A and

1.3 A

Coil Currents Rated at >1.3 A and

3.0 A

Compatible Brake Motors

(1)

Coil Current

Compatible Brake Motors/Actuators

Coil Current

MPL-x1510, MPL-x1520, MPL-x1530

0.43…0.53 A

MPG-x004

0.30…0.36 A

MPL-x210, MPL-x220, MPL-x230

0.46…0.56 A

MPG-x010

0.41…0.49 A

MPL/MPF-x310, MPL/MPF-x320, MPL/MPF-x330

0.45…0.55 A

MPG-x025

MPS-x330

MPG-x050

0.45…0.55 A

MPL-x420, MPL-x430, MPL-x4520, MPL-x4530,
MPL-x4540, MPL-B4560

0.576…0.704 A

MPG-x110

0.90…1.10 A

MPF-x430, MPF-x4530, MPF-x4540

TLY-A110-H, TLY-A120-H, and TLY-A130-H

0.18…0.22 A

MPS-x4540

TLY-A220-H and TLY-A230-H

0.333…0.407 A

1326AB-B4xxx

0.88 A

TLY-A2530-H and TLY-A2540-H

0.351…0.429 A

F-4030, F-4050, and F-4075

0.69 A

TLY-A410-H

0.648…0.792 A

(1)

Use of the variable x indicates this specification applies to 230V and 460V motors.

Compatible Brake Motors

Coil Current

Compatible Brake Motors

Coil Current

MPL-x520, MPL-x540, MPL-x560, MPL-x580

(1)

1.05…1.28 A

F-6100, F-6200, and F-6300

1.30 A

MPF-x540

(1)

1326AB-B5xxx and 1326AB-B7xxx

1.20 A

MPS-B560

(1)

Use of the variable x indicates this specification applies to 230V and 460V motors.

Compatible Brake Motors

Coil Current

MPL-B640, MPL-B660, and MPL-B680

1.91…2.19 A

MPL-B860 and MPL-B880

MPL-B960 and MPL-B980

Advertising