Configuring your logix analog motion module – Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual

Page 53

Advertising
background image

Publication 2098-IN005C-EN-P — March 2008

Commissioning Your Ultra3000 Drive

53

Configuring Your Logix Analog Motion Module

This procedure assumes that you have finished configuring your
Ultra3000 drive.

For help using RSLogix 5000 software as it applies to configuring the
Logix analog modules, refer to Additional Resources on page 8.

Configure Your Logix Controller

Follow these steps to configure your Logix controller.

1. Apply power to your Logix chassis containing the analog motion

module and open your RSLogix 5000 software.

2. From the File menu, choose New.

The New Controller dialog opens. The ControlLogix 1756-L63
controller was used in this example.

3. Configure the new controller.

a. From the Type pull-down menu, choose your controller.

b. From the Revision pull-down menu, choose your

RSLogix 5000 software version.

c. In the Name box, name your file.

d. From the Chassis Type pull-down menu, choose your Logix

chassis.

e. Enter the Logix processor slot.

4. Click OK.

5. From the Edit menu, choose Controller Properties.