Publication 2098-IN005C-EN-P — March 2008

Commissioning Your Ultra3000 Drive

55

Configure Your Logix Module

Follow these steps to configure your Logix module.

1. In the Explorer dialog, right-click I/O Configuration and choose

New Module.

The Select Module dialog opens.

2. Expand the Motion category and select 1756-M02AE, 1756-HYD02,

1756-M02AS, or 1784-PM02AE as appropriate for your actual
hardware configuration.

3. Click OK.

Your new module appears under the I/O Configuration folder in
the Explorer dialog and the New Module dialog opens.

4. Configure the new module.

a. In the Name box, enter your module name

b. Enter the module slot.

c. From the Electronic Keying pull-down menu, choose your

keying option

5. Click OK.

Your new module appears under the I/O Configuration folder in
the Explorer dialog and the Module Properties dialog opens.