Wiring the vac load (opl) connector – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 78

Advertising
background image

Publication 2093-UM001A-EN-P — January 2007

78

Connecting the Kinetix 2000 Drive System

VAC LINE (IPL) Connector (2094-AL09, 2094-ALxxS, and 2094-XL75S-Cx)

Wiring the VAC LOAD (OPL) Connector

Line Interface Module (OPL connector)

VAC LOAD (OPL) Connector (2094-ALxxS, or 2094-XL75S-Cx)

Three-phase Supply

IPL Pin

Signal

Recommended Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
Nm (lb-in.)

L1

4

L1

2.5...25 (14...4)

16.0 (0.63)

2.7 (24)

L2

3

L2

L3

2

L3

1

L3

L2

L1

1 2 3 4

Line Interface Module, Top View
(2094-XL75S-Cx is shown)

IMPORTANT

Line interface modules (2094-ALxxS, and 2094-XL75S-Cx) are capable
of connecting to two IAMs, providing each IAM has its own line filter
and the maximum current specification is not exceeded.

Refer to Power Wiring Examples on page 169 for an example of the
LIM wired to two IAMs.

Three-phase Supply

OPL Pin

Signal

Recommended Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
Nm (lb-in.)

L1

4

L1’

2.5...25 (14...4)

16.0 (0.63)

2.7 (24)

L2

3

L2’

L3

2

L3’

1