Wiring the input power (ipd) connector – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 82

Advertising
background image

Publication 2093-UM001A-EN-P — January 2007

82

Connecting the Kinetix 2000 Drive System

Wiring the Input Power (IPD) Connector

This example applies to an integrated axis module (IAM) or leader IAM (dc
common bus).

Integrated Axis Module (IPD connector)

Input Power (IPD) Connections

Termination Specifications

IPD Connector

(IAM or leader IAM)

OPL Connector (LIM) or

Other Three-phase Input

2094-ALxxS, or
2094-XL75S-Cx

IPD Pin

Signal

OPL Pin

Signal

1 L1

4

L1

2 L2

3

L2

3 L3

2

L3

4 1

5 DC+

N/A

6 DC-

Integrated Axis Module
Cat. No.

Input V ac

Recommended
Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
Nm (lb-in.)

2093-AC05-MPx

230V ac

2.5 (14)

7 (0.28)

0.5 (4.4)

L1

L2

L3

GRND

DC+

DC-

1 2 3 4 5 6

Integrated Axis Module

(2093-AC05-MPx shown)

Advertising