Wiring feedback and i/o connectors, Connecting premolded motor feedback cables, Wiring low-profile connector kits – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 95

Advertising
background image

Publication 2093-UM001A-EN-P — January 2007

Connecting the Kinetix 2000 Drive System

95

Wiring Feedback and I/O
Connectors

These procedures assume you have mounted your Kinetix 2000 system,
completed all power wiring, and are ready to connect your feedback and I/O
cables.

Connecting Premolded Motor Feedback Cables

Motor feedback cables with premolded connectors plug directly into 15-pin
motor feedback (MF) connectors on either the IAM or AM (no wiring is
necessary).

Premolded Feedback Cable Attached to MF Connector

Wiring Low-profile Connector Kits

Low-profile connector kits (2090-K2CK-D15M) are suitable for motor
feedback (MF), connections on any IAM or AM.

For this connection

Go To

Premolded cable

Connecting Premolded Motor Feedback Cables on page 95.

Low-profile connector

Wiring Low-profile Connector Kits on page 95.

Panel-mounted breakout board

Wiring 15-pin Panel-mounted Breakout Kit on page 97.

IMPORTANT

When using Bulletin 2090 cables with premolded connectors, tighten
the mounting screws (finger tight) to improve system performance.

Integrated Axis Module,
Front View
(2093-ACO5-MPx is shown)

Motor Feedback (MF) Connector

Premolded Connector
(2090-UXNFBMP-S

xx cable)

Integrated Axis Module, Side View
(2093-AC05-MPx is shown,
Power and I/O connectors removed)

Advertising