Alarm status – AJA Ki Pro User Manual

Page 44

Advertising
background image

Ki Pro v3.2

www.aja.com

44

Line 2: Status (Record) displays the record format; the 4 characters on the right display

the selected audio input: SDI, XLR, RCA, or HDMI.

Second STATUS page—shows the timecode setting prior to recording. With the STATUS

button selected, press SELECT up to see the second page.

Here are some STATUS display examples:

The first STATUS page shows the format and frame rate of the material being recorded or
played back. The second page shows the timecode settings. The third page may show
the Interval Record status (if Interval Record is enabled).

Alarm Status

The Alarm menu displays warnings and alarms. Some alarms will automatically be shown
on the display. Others will only be seen by checking the STATUS displays (press Select up/
down to cycle through them). If everything is OK, then a “SYSTEM NORMAL” message will
be seen when you cycle through the STATUS displays.

You will be alerted to an alarm condition by having all backlit keys and the display flash
to full intensity for 2 seconds. If more than one alarm state is active, then the display will
hold each alarm notification for 3 seconds before cycling to the next alarm. These alarm
notifications override whatever the display is currently showing for the TRANSPORT or
STATUS menus. Once there is a Ki Pro alarm active (e.g. Invalid Selection) the STATUS
button light will blink for as long as the alarm is present. This alerts you so you’ll know
the reasons for the alarm condition are still active—you can then press the STATUS
button to determine what the alarm condition is.

CONFIG and MEDIA menus, once entered after an alarm notification, will cause the alarm
display to go away. Pushing any button always returns Ki Pro to its pre-alarm state—
however, if the alarm condition still exists after this initial button push (i.e., the reason for
the alarm), the alarm notification will reappear on the display. Note: the STATUS button
will blink if there is an active alarm condition.

Media Format

Output Conversion mode

IN 720p 59.94

SDI

REC 1080i 29.97

XLR

Play Mode

Record Mode

TC In

TC Value

01:00:00:00

Second STATUS page: Timecode setting prior to recording

Interval Record Enabled

Interval:1

Time: Sec

Third STATUS page: Interval record status (if enabled)