Balboa Water Group GL8000 Configuration Guides User Manual

Instruments balboa, Gl8000 expansion options, Incorporated

Advertising
background image

Output Features

Quadrant

J1

2-Speed Pump 1

3-A

J2

Output tied to Pump 1 Low

4-A

– OR output tied to Circ Pump (Set with J39)

J3

Circ Pump

3-A

J4

Ozone

5-A

J5

A.V.

2-C

J6

Blower

7-B

J10 Spa Light (10V or 230V)

8-C

J7

Misc (Separate Relay 10V or 230V)

7-E

J8

Fiber Optic (10V or 230V)

7-F

J9

Mister (10V or 230V)

9-A

J11 2-Speed Pump 2

4-C

J12 2-Speed Pump 3

5-C

Soldered-In Jumper Application

Quadrants

J29 + J50

Determine Voltage for J9 (Mist)

8-A, 8-B

J37 + J38

Determine Voltage for J10 (Spa Light)

Unused

Light Votage is determined with W1 & W2

J47 + J52

Determine Voltage for J7 (Misc.)

5-E, 7-E

J49 + J46

Determine Voltage for J8 (Fiber Optic)

5-F, 7-F

GL8000 Mach 3 Configuration Guide

GL8000 Expansion Options

Instruments

Balboa

Incorporated

Document PN 40619_H

04-06-2007

Pump 5

P

ump 2

To

J

1

1

PS-25
Used to split the output from the Pump 2 Connector (J11)
into a single-speed Pump 2 and single-speed Pump 5.
White wire quick connect goes to Main PCB at J59.

PN 25094

White

Red

White

Green
Black

Green

PS-34
Used to split the output from the Pump 3 Connector (J12)
into a single-speed Pump 3 and single-speed Pump 4.
White wire quick connect goes to Main PCB at J58.

PN 25093

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

3

2

1

Soldered-In Jumper Configuration

Locations 1 & 2 determine 10VAC, Locations 2 & 3 determine 230VAC.

10 VAC
Spa Light Configuration

230 VAC
Spa Light Configuration

ELS-VALVE
Used to split the output from a single-speed Pump to allow
a Valve Sequencer to be powered by the pump’s output.

PN 22934

PN 53914

X-Mount M
Used for mounting any Expander Board
in a metal enclosure.
Bracket attaches to heater mounting straps

X-P632 CE
Used for an additional 2-speed Pump output.
Relay control J2 plugs into the EXP I/O connector J36 on
the Main PCBA (Quadrant 7-G).

PN 55026

X-P231 CE
Can replace the X-P CE in cases where branch circuit protection
is needed for high amperage devices that would over-burden
power input fuse F6 or F7 (3-D) on the main PCBA.

PN 55025

X-P CE
Used add a additional 1-speed Pump output when all
main board pump connections are used.

PN 53547

G

R

B

W

J1

W1

J2

J6

T30A 480V

X-P632 CE
PN 55026

P/N 22909 REV B

ADCM SPLITTER KIT
Required when using a Menu-driven panel.
Kit includes PCB, stand-offs, and cable.
Note: Software v29 or higher required.
• J2 connects to ADCM IN (J69) on main PCBA.
• J3 connects to Menu Panel or Transceiver.
• J6 connects to tester or F.A.S.T. station.

PN 54530

J6

J3

J2

J1

TEST

Balboa

MADE IN U.S.A.
P/N 22039_ A

© 2006

ADCM SPLITTER
PN 54530

Balboa

J94

J95

TB1

J96

K9

K10

K5

K13

J25

K15

K1

J82

J15

J22

J24

RLY

AUX. F

SEN. A

VAC

SEN. B

J83

C45

CFG

J91

J17

TST

SWITCHBANK A

SWITCHBANK B

J35

ALARM

J19

UV

J18

TV1

J51

J21

TV2

F1

G

N

G

N

G

N

G

N

G

N

G

N

G

N

J14

J16

G

N

F7

F6

F7,

T30A

480V

F6, T30A 480V

F9

F9,

T30A

480V

K4

K2

K3

K11

J1

J12

J11

J5

BALBOA INSTRUMENTS, INC.

GL8000 Mach III

COPYRIGHT 2006

P/N 22960_C

MADE IN U.S.A.

K6

K8

K7

J27

J79

J59

J23

J28

J26

J32

J13
J30

J57

J58

J90

HTR2

HTR1

J54

J53

G

N

G

N

J39

1 2 3

J3

J2

J4

J56

J55

J60

J75

J76

J62

J14

J74

F5, F10A 250V

F5

F4

3

2

1

3

2

1

3

2

1

3

2

1

F4, F3A 250V

J33

J41

J81

J45

J29

J50

J37

J10

J38

3

2

1

3

2

1

3

2

1

M1

M11

3

2

1

J52

J7

G

N

J8

J47

J49

1

2

3

4

J46

BARCODE

W1

N

G

J84

W2

J36

EXT I/O

MAIN P

ANELS

AUX P

ANELS

J72

J73

J71

J70

J16

J40

J34

J31

ADCM

REMOTE

J69

J20

F2

F2, T0.5A 250V

J77

J9

J6

M15

M16

M5

M7

M4

M8

M3

M2

M10

M12

K10

K15

G

R

B

W

G

R

B

W

J56

F5, F10A 250V

F5

F4

F4, F3A 250V

J10

W1

N

G

W2

J33

J45

J60

K10

K15

G

R

B

W

G

R

B

W

J56

F5, F10A 250V

F5

F4

F4, F3A 250V

J10

W1

W2

J33

J45

J60

N

G

Advertising