APPENDIx B: J1587 SID and FMI Codes and their Bendix Blink Code Equivalents

SID

(J1587)

SPN

(J1939)

FMI

(J1587/

J1939)

Bendix Blink Code

Equivalent(s)

Diagnostic Trouble Code Description

(1st Digit) (2nd Digit)

Miscellaneous DTCs

55

1045

2

12

2

Stop Lamp Switch Defective

55

1045

4

12

27

Brake Lamp Input Mismatch with Brake Lamp Output

55

1045

7

12

1

Stop Lamp Switch Not Detected

Pressure Modulator Valve DTCs

66

1056

3

20

2

Trailer PMV REL Solenoid Shorted to Voltage

66

1056

3

20

5

Trailer PMV HLD Solenoid Shorted to Voltage

66

1056

4

20

1

Trailer PMV REL Solenoid Shorted to Ground

66

1056

4

20

4

Trailer PMV HLD Solenoid Shorted to Ground

66

1056

5

20

3

Trailer PMV REL Solenoid Open Circuit

66

1056

5

20

6

Trailer PMV HLD Solenoid Open Circuit

66

1056

5

20

7

Trailer PMV CMN Open Circuit

66

1056

7

20

8

PMV Configuration Error

For more Pressure Modulator Valve DTCs - see SID 93 below...

Brake Demand/Load Sensor DTCs

69

1059

2

24

3

Open or Shorted Load Sensor

77

1067

2

24

1

Shorted Brake Demand Sensor (Primary CKT) Open

77

1067

2

24

5

PS Supply Voltage Error

77

1067

7

24

6

PS Not Calibrated

77

1067

11

24

4

Plausibility Error Brake Demand Sensor

78

1068

2

24

2

Shorted Brake Demand Sensor (Secondary CKT) Open

Miscellaneous DTCs

79

1069

13

12

10

Tire Size Out of Range (Front to Rear)

Steering Angle Sensor DTCs

89

1807

2

21

3

SAS Static Signal

89

1807

2

21

4

SAS Signal Out of Range

89

1807

2

21

5

SAS Signal Reversed

89

1807

2

21

7

SAS Gradient Error

89

1807

2

21

9

SAS Long Term Calibration Error

89

1807

2

21

10

SAS Plausibility Check (Ref Yaw Rate)

89

1807

9

21

8

SAS CAN Timeout

89

1807

12

21

6

SAS Invalid Signal

89

1807

13

21

1

SAS Not Calibrated

89

1807

13

21

2

Steering Angle Sensor Calibration Not Finished

89

1808

13

22

15

YRS Sign Check Not Finished

Pressure Modulator Valve DTCs

93

802

3

12

8

PMV Common Shorted to Voltage

93

802

4

12

7

PMV Common Shorted to Ground

HSA DTCs

94

2622

2

12

4

HSA lamp shorted to ground or broken wire

94

2622

3

12

5

HSA lamp shorted to Voltage

94

2622

3

12

24

HSA solenoid shorted to Voltage (total shutdown)

94

2622

3

12

26

HSA solenoid shorted to Voltage (ATC & ESP shutdown)

94

2622

5

12

25

HSA solenoid shorted to ground or broken wire

94

2622

13

12

24

HSA solenoid shorted to Voltage

Lateral Acceleration Sensor DTCs

99

1809

2

23

1

LAS Signal Out of Range

99

1809

2

23

3

LAS Static Calibration Error

99

1809

2

23

4

LAS Long Term Calibration Error

99

1809

2

23

5

LAS Plausibility Error (Inside ECU-Specific Limits)

99

1809

2

23

6

LAS Plausibility Error (Outside ECU-Specific Limits)

99

1809

13

23

2

LAS Calibration in Progress

99

1808

14

23

7

Erratic ESP Sensor Signal

Advertising