Bryant 575B User Manual

Wiring diagrams, Split-system heat pump units

Advertising
background image

Cancels: WD 575C.90.1

WD 575B.72.1

6/15/03

DIAGRAM INDEX

*Units produced after 3/31/03.

LEGEND (Fig. 1-9)

NOTES (Fig. 1 and 2)

1. Factory wiring is in accordance with National Electri-

cal Code (NEC). Field modifications or additions
must be in compliance with all applicable codes.

2. Use copper conductors only.

3. CAUTION: Not suitable for use on systems exceeding

150 volts to ground.

4. Manual reset circuit breaker is integral to the

transformer.

NOTES (Fig. 3-8)

1. If any of the original wire furnished must be

replaced, it must be replaced with type 90° C wire or
its equivalent.

2. For thermostat and subbase part no. see price pages.

3. Set heat anticipator at .6.

4. Use copper conductors only.

5. Three-phase motors are protected under primary

single phasing conditions.

6. 39 VA available for field-installed accessories. Control

power requirement for heat pump condensing unit is
36 VA (sealed). Supplied control transformer is 75 VA.

NOTES (Fig. 9)

1. Factory wiring is in accordance with National Electri-

cal Code (NEC). Field modifications or additions
must be in compliance with all applicable codes.

2. Use copper conductors only.

UNIT

SIZE

ELECTRICAL

CHARACTERISTICS

(V-Ph-Hz)

TYPE

LABEL DIAGRAM

NUMBER

FIGURE NO.

575B

072

208/230-3-60

Control Schematic and Component Arrangement

Not available

1

460-3-60

2

575-3-60

2

575C

090-120

208/230-3-60

Control Schematic and Component Arrangement

38AK540179

3 or 4*

460-3-60

38AK540180

5 or 6*

575-3-60

38AK540211

7 or 8*

524A-H

090-120

Applies to all

Unit Wiring Diagram

Not Available

9

C

Contactor, Compressor

CAP

Capacitor

CB

Circuit Breaker

CCH, CH — Crankcase Heater
CDT

Contactor Dummy Terminal

CLO

Compressor Lockout

COMP

Compressor

CTD

Compressor Time Delay

DFC

Defrost Control

DFT

Defrost Thermostat

DGT

Discharge Gas Thermostat

EQUIP

Equipment

FM

Fan Motor

GND

Ground

HP, HPS — High-Pressure Switch
IFC

Indoor-Fan Contactor

IFM

Indoor-Fan Motor

LAR

Low Ambient Relay

LAS

Low Ambient Switch

LCS

Loss-of-Charge Switch

LLSV

Liquid Line Solenoid Valve

LP, LPS

Low-Pressure Switch

MMR

Motormaster® Relay

NEC

National Electrical Code

OF, OFM — Outdoor-Fan Motor
OFR

Outdoor-Fan Relay

PL

Plug

PS

Pressure Switch

RV

Reversing Valve

RVS

Reversing Valve Solenoid

TB

Terminal Block

TRAN(S) — Transformer
T’STAT

Thermostat

Field Splice

Marked Wire

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice
Factory Power Wiring
Factory Control Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential only,
not to represent wiring.

wiring diagrams

SPLIT-SYSTEM HEAT PUMP UNITS

575C/575B

Sizes 072 to 120

with

524A-H