Trouble on operation, Eng -66 – CatEye Q3 User Manual

Page 67

Advertising
background image

ENG-66

Trouble on operation

Trouble

Check Items

Remedy

Pressing and holding the

MODE1 or MODE2 button

does not turn on a light.

Check whether the Setup

mode is displayed (page 48).

The backlight does not turn on in the Setup

mode.

Check whether

lights up

on the wristwatch screen.

The remaining battery capacity of the wrist-

watch is low. Replace it with a new battery

(CR2430). After replacement, be sure to per-

form the restarting operation (page 13).

Pressing the SSS button

does not start/stop mea-

surement.

Check whether the auto-

mode is turned on (with

illuminating).

When the auto-mode is on (

icon appears), you

cannot start or stop the measurement by pressing the

button. To start/stop measurement by pressing the

SSS button, switch the auto-mode to off (page 57).

The heart rate sensor

(speed sensor) ID check

failed.

The battery for the heart rate sensor (speed sensor) is

possibly depleted. After replacing the battery with a new

one (CR2032), check the sensor ID again (page 52).

Lap data cannot be stored. Check whether “--” appears for

the Lap No. screen.

The data volume exceeds the wristwatch

memory capacity. Delete the files (page 44).

When using the optional “USB communica-

*

tion kit”, delete the files after you send the

saved files to your PC.

Does the lap time exceed 100

hours (or the interval distance

exceed 9999.99 km/mile) ?

Laps cannot be measured, if recordable range

described on the left is exceeded. Reset the data

(page 26), and then perform measurement again.

Is it immediately after press-

ing the LAP button?

Recording laps needs at least 5 seconds of

interval.

Abnormal values appear.

Are there any objects emitting

electromagnetic waves (railway

tracks, transmitting stations for

television, etc.) nearby?

Keep the unit away from any object that may

be causing interference, and reset the data

(page 26).

Any setting cannot be

changed in Option mode

or Setup mode.

Is it during measurement?

Settings can be only viewed during the mea-

surement.

Check whether the auto-

mode is on ( lights up).

When the auto-mode is on ( lights up), the

wristwatch may enter measurement mode due

to electromagnetic waves. Keep the unit away

from any object that may be causing interfer-

ence with electromagnetic waves.

Check whether “DATA RESET

is displayed.

To change the target heart rate zone, measure-

ment unit, and record interval, the resetting

operation is required. Stop the measurement,

and perform the resetting operation (page 26).

The record data in the File

view cannot be viewed to

the end.

Check whether

MEMORY FULL” is

displayed on the screen

during measurement.

The data volume exceeds the wristwatch memory capac-

ity. The data was saved automatically during measure-

ment, and any subsequent data was no longer recorded.

Delete the files for subsequent measurement (page 44).

When using the optional “USB communica-

*

tion kit”, delete the files after you send the

saved files to your PC.