Universal Reset Control 363

- Data Brochure

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

heating system. The control automatically adjusts the boiler and mixed loop water temperatures that are delivered to the heating system

by using outdoor reset. For a mixing device, the 363 can use a variable speed driven wet-rotor circulator or a floating action driven mixing

valve. The 363 is capable of controlling an indirect Domestic Hot Water (DHW) storage tank and / or a setpoint load. The temperature of

individual zones can be controlled by connecting a conventional thermostat system or a tekmar Zone Control to the 363.

The 363 control includes a large Liquid Crystal Display (LCD) in order to view system status and operating information. The LCD and user

key pad are used to set the control’s adjustment and to monitor pump and boiler running hours, DHW tank temperatures, outdoor and

system high and low temperatures, boiler firing cycles, plus many other useful items.

Several energy saving features have been incorporated into the 363 such as Warm Weather Shut Down (WWSD), DHW post purge,

system setback, DHW priority, Morning Boost, Soft Start and an automatic differential for boiler control. The 363 also has a unique feature

that allows the control to supply heat to the mixed system from either the boiler or a thermal storage tank.

LR 58233 E150539

70

M

M

Input

120 V (ac)

Power

Supply

Input

(BOIL

or MIX)

tekmar Zone

Control

Output

Mixed System

Pump

Output

Boiler

Input

Outdoor

Sensor

Included

Input

Universal

Sensor

Included

Input (MIX)

tekmar Indoor

Sensor

Input

Mix Demand

signal

Output

Var. Speed

Driven Pump

Output

DHW Pump OR

DHW Valve

Input

tekmar

Timer

Output

Boiler System

Pump

Input

Boiler

Demand

signal

Output

Mixing Valve &

Actuating Motor

Input

Setpoint or

DHW

Demand

signal

OR

Input

Universal

Sensor

Included

Input (MIX)

tekmar Slab

Sensor

Input

Universal

Sensor

(optional)

Input (MIX)

Room

Temperature

Unit (RTU)

Input

Remote

Display

Module (RDM)

OR

Item

Menu

°F

Vie

!

WWS

1

%

%

2

Item

Menu

°F

Vie

!

WWS

1

%

%

2

OR

OR

UnOc

Open

°

F

1

View

2

1

%

7

Power

115 V ±10% 60 Hz 1800 VA

Relays

230 V (ac) 7.5 A 1/3 hp, pilot duty 240 VA

Var. Pump

230 V (ac) 2.4 A 1/6 hp, fuse T2.5 A 250V

Demands

20 to 260 V (ac) 2 VA

Test

not testing
testing
testing paused

off

red
red

2 3

1

Com

Dem

4

Mix

Demand

Boil

P1

13

Pwr

Mix

15

Power

N L

18

Com

19

tN1/

tN2

20

10K

2

21

10K

1

22 23

Com

24

Mix

25

Boil

Universal Reset Control 363

Mixing, Boiler & DHW

6

10

12

14

16

Boiler

Opn Cls/

Var

DHW

Pmp / Vlv

Boil

Dem

Setp/

DHW

Mix Demand
Boiler Demand
DHW Demand
Setpoint Demand
WWSD
Minimum
Maximum

5

Do not apply power

Menu Item

Reset Ratio

Setback

Characterized

Heating Curve

None

Mix

P2

8

11

9

17

Com

UnO

Sw

26

Out

DHW

R

C US

For maximum heat,

press and hold

Test

button for 3 seconds.

Note:

Boiler, DHW, setpoint, or

mix demand must be

powered with 20 to 260

V (ac) before the control

will operate pump/valve

outputs or the boiler is

able to fire.

See product literature

INSTALLATION CATEGORY II

Made in Canada by

tekmar Control Systems Ltd.

tektra 929-05

Signal wiring must be rated at least 300 V.

Supply wiring must be rated 90°C minimum

Da

te Code

H1153E

Meets Class B:

Canadian ICES

FCC Part 15