1.0 SPECIAL NOTICES

1.1 The following special notices highlight

important information in the installation and

maintenance sections. Each serves a special

purpose and is displayed in the format shown:
This symbol indicates a potentially hazardous

situation, which, if not avoided, can result in

personal injury or damage to the equipment.
This symbol indicates a potentially hazardous

situation, which, if not avoided, may be a

shock hazard.
This symbol indicates an imminently hazardous

situation, which, if not avoided, could result in

death or serious injury.

2.0 PRE-INSTALLATION

2.1 Initially, inspect the heater for possible

damage due to shipping and handling. Claims

for shipping damages shall be placed with the

carrier.

2.2 Check the heater nameplate to ensure that

the heater area classification and temperature

code are suitable for the hazardous area

classification. For details of hazardous

locations with potential for explosion, refer

to the Canadian Electrical Code or National

Electrical Code.

2.3 Check to ensure that the heater voltage is the

same as the supply voltage.

2.4 The heater must be installed by qualified

personnel in strict compliance with national

and local electrical codes.

WARNING

DO NOT CONNECT THE HEATER TO AN

ELECTRICAL SUPPLY VOLTAGE OTHER

THAN THAT SHOWN ON THE PRODUCT

NAMEPLATE.

3.0 INSTALLATION - GENERAL REQUIREMENTS

3.1 Norseman

TM

XB heaters are approved for wall

or floor mounting with the terminal housing at

the bottom. Ensure that is the wall sufficiently

strong to support the heater which, depending

on the model, could weigh up to 100 lbs (45

kg). Otherwise use the brackets supplied to

stand the heater on the floor.

3.2 Do not recess the Norseman

TM

XB heater

into the wall. Use of the brackets supplied will

ensure that the minimum spacing from the

wall of 3.75” (95 mm) is maintained.

3.3 If more than one heater is being installed,

maintain at least 3” (76 mm) between adjacent

heater extrusions. NEVER INSTALL ONE

HEATER ABOVE THE OTHER.

3.4 The Norseman

TM

XB heater relies on natural

convection and “black heat” radiation to transfer

heat to the surroundings. Try to maintain a 12”

(300 mm) clearance and NEVER LESS THAN

6” (150 mm) clearance in front of and at the

sides of the heater.

3.5 Use guard rails in front of the heater if there

is a possibility that moving equipment could

come in contact with the heater.