Monarch Instrument MT-190 User Manual

M-190w magnetic sensor

Advertising
background image

M-190W Magnetic Sensor

SPECIFICATIONS:

Speed Range:

1-99,999 RPM

Operating Distance:

0.005” [0.127 mm] gap from target

Minimum Target Size:

0.106” [2.692 mm] minimum diameter

Power required:

None - Self Generating AC voltage

Output Signal:

190V P-P maximum

Pole Piece Magnet Diameter: 0.106 inch [2.692 mm]
Operating Temperature:

-100° to 225° F [-73° to 107° C]

Standard Cable Length:

8 feet [2.438 m]

Dimensions:

2.0” (L) x 0.625” [50.8 x 15.875 mm]

Weight:

3 oz [85 g]

Specifications are subject to change without notice.

OVERVIEW:

The M-190W Magnetic Sensor is a self-powered gear sensor that is most popular for use with 60 tooth 20 pitch gears. The sensor mounts
within 0.005 inches [0.127 mm] of a minimum 0.106 inch [2.692 mm] diameter ferrous target. The sensor self-generates an AC signal and
requires no power from the display module.

The M-190W is compatible with all Monarch ACT Series panel tachometers and MT-190 Magnetic Trigger Sensor/Amplifier models.

CONNECTION DETAIL:

Wire Color

Function

Black

AC Signal

White

AC Signal

Shield

Housing Ground

When using the M-190W with any Monarch ACT Series panel tachometer, refer to the panel tachometer instruction manual for sensor
connection detail.

OPERATION:

Magnetic sensors convert motion of a ferrous target into an AC voltage output proportional to speed. The target must not be smaller than
the magnetic poll piece (0.106 inches, 2.692 mm) or larger than the diameter of the sensor (0.625 inches, 15.875 mm). Gear teeth are
preferred, but bolt heads, slots or keys also work. The Monarch ACT Series panel tachometers will typically operate from all 2-wire design
magnetic sensors. The stainless steel and waterproof housing of the M-190W sensor allow operation in harsh locations. The user can
increase the cable length up to a total of 500 feet [152.4 m] in length.

In order to comply with EU Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE):
This product may contain material which could be hazardous to human health and the environment. DO NOT DISPOSE of
this product as unsorted municipal waste. This product needs to be RECYCLED in accordance with local regulations, contact
your local authorities for more information. This product may be returnable to your distributor for recycling - contact the
distributor for details.

Figure 1 M-190W Dimensions

MONARCH INSTRUMENT * 15 Columbia Drive * Amherst, NH 03031 USA * Tel: (603) 883-3390 * Fax: (603) 886-3300

E-mail: [email protected] * Website: www.monarchinstrument.com

1071-4853-112R (0609)